If throttling of outgoing messages is configured, FIX Antenna sends to the counterparty the particular amount of messages (MessagesLimit) within the specified time interval (IntervalMs) using the mechanism defined in the Type property.
If the amount of sent FIX messages exceeds the specified MessagesLimit within the configured time interval then the outgoing message will be added to the queue.
...
If at least one of these parameters is specified with an incorrect value then the FIX session will not be created.
Log messages
If the MessagesLimit or IntervalMs property is specified with an incorrect value, the warning below will be logged:
Code Block |
---|
WARN [EngineAdaptor] <Session_Name> session cannot be started now. Reason: <parameter>: max items in interval cannot be <value> |
If the Direction or Type property is specified with an incorrect value, the error below will be logged:
Code Block |
---|
ERROR [EngineAdaptor] <Session_Name> session can't be configured and won't be started because: invalid value of parameter <parameter> |
If at least one of MessagesLimit, IntervalMs, Direction, and Type properties is absent, then the error below will be logged:
...