Configure throttling of outgoing messages
Info |
---|
Throttling of outgoing messages is available since FIX Antenna 2.30.0 release. |
Throttling of outgoing messages allows limiting the amount of sent FIX messages within a time interval.
...
If the amount of sent FIX messages exceeds the specified MessagesLimit within the configured time interval IntervalMs then the outgoing message will be added to the queue.
...
If at least one of these parameters is specified with an incorrect value then the FIX session will not be created.
Configure throttling of incoming messages
Info |
---|
Throttling incoming messages is available since FIX Antenna 2.31.0 release. |
Throttling incoming messages allows limiting the amount of received FIX messages within a time interval.
Overview
If throttling of incoming messages is configured for the session, FIX Antenna receives from the counterparty the particular amount of messages (MessagesLimit) within the specified time interval (IntervalMs) using the mechanism defined in the Type property.
If the amount of received FIX messages exceeds the specified MessagesLimit within the configured IntervalMs then the onIncomingThrottling callback with the particular DefaultAction will be called.
When configuring several throttlers for the session, they must be listed in the Throttlers parameter in the order of severity.
Configuration example
Throttling properties must be configured in the engine.properties file:
Code Block | ||
---|---|---|
| ||
Session.<SenderId>/<TargetId>.Throttlers = MyGeneralInLimiter1, MyGeneralInLimiter2 Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter1.Direction = Incoming Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter1.Type = SlidingWindowMessages # throttler type dependent parameters Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter1.MessagesLimit = 10000 Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter1.IntervalMs = 10000 Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter1.DefaultAction = TerminateWithLogout Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter2.Direction = Incoming Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter2.Type = SlidingWindowMessages # throttler type dependent parameters Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter2.MessagesLimit = 100 Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter2.IntervalMs = 10000 Session.<SenderId>/<TargetId>.Throttlers.MyGeneralInLimiter2.DefaultAction = SendReject |
Log messages
If the MessagesLimit or IntervalMs property is specified with an incorrect value, the warning below will be logged:
Code Block |
---|
WARN <Session_Name> session cannot be started now. Reason: <parameter>: max items in interval cannot be <value>. |
If the Direction, Type or Type DefaultAction property is specified with an incorrect value, the error below will be logged:
...
If at least one of MessagesLimit, IntervalMs, Direction, and Type properties is absent, then the error below will be logged:
...