This article is applicable for FIX Antenna C++/.NET versions earlier than 2.13.0 and for FIXEdge versions earlier than 5.9.0. If you have a newer version of the product, please consider this article as obsolete and take a look on https://kb.b2bits.com/display/B2BITS/How+to+configure+SSL+for+FIX+session+in+FIXEdge.


Simple configuration FIXEdge -> Stunnel -> SSL acceptor

Install stunnel

Download latest version installer from https://www.stunnel.org/downloads.html

Run installer and answer questions to generate certificate.

Configure stunnel

Initiator FIX session

  • Run stunnel GUI Start from Start menuRun  
  • Edit stunnel.conf from stunnel system tray icon context menu
    • Add option 
      protocol = proxy
    • Comment example SSL services
    • Add SSL service
      [fix_initiator_session1_tunnel]
      client = yes
      accept  = 127.0.0.1:443
      connect = 63.247.113.201:443
  • Run Reload stunnel.conf from stunnel system tray icon context menu

Configure fix session

Initiator FIX session

FIXEdge.properties
FixLayer.FixEngine.Session.SSLInitiator.Role = Initiator
FixLayer.FixEngine.Session.SSLInitiator.Host = 127.0.0.1
FixLayer.FixEngine.Session.SSLInitiator.Port = 443

Complex configuration: Broker/Stock -> Broker's/Stock's Stunnel -> FIXEdge's Stunnel -> FIXEdge -> FIXEdge's Stunnel -> Broker's/Stock's Stunnel -> Broker/Stock

Server F (FIXEDGE):  y.y.y.y where FIXEdge is installed

Server B (BROKER):  x.x.x.x where SimpleClient #1 and SimpleClient #2 are installed. SimpleClient #1 will simulate Broker and SimpleClient #2 will simulate StockExchange.

Server F (FIXEDGE) Configuration

FIXEdge.properties

# -----------------[ SC1 AS ACCEPTOR SEND MESSAGE TO SC2 ] ------------------
FixLayer.FixEngine.Session.FIXEDGE-SC1.Version = FIX44
FixLayer.FixEngine.Session.FIXEDGE-SC1.EncryptMethod = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.ForceSeqNumReset = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.IgnoreSeqNumTooLowAtLogon = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.IntradayLogoutTolerance = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.MaxMessagesAmountInBunch = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.RecreateOnLogout = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.TerminateOnLogout = true
FixLayer.FixEngine.Session.FIXEDGE-SC1.RejectMessageWhileNoConnection = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.Role = Acceptor
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderCompID = FIXEDGE
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.SocketPriority = EVEN
FixLayer.FixEngine.Session.FIXEDGE-SC1.SecurityGroups =
FixLayer.FixEngine.Session.FIXEDGE-SC1.StorageType = persistentmm
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetCompID = SC1
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.TcpBufferDisabled = false

# ----------------- [SC2 AS  INITIATOR RECEIVED MESSAGES SENT FROM  SC1] ----------
FixLayer.FixEngine.Session.FIXEDGE-SC2.Version = FIX44
FixLayer.FixEngine.Session.FIXEDGE-SC2.EncryptMethod = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.ForceReconnect = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.ForceSeqNumReset = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.HBI = 30
FixLayer.FixEngine.Session.FIXEDGE-SC2.Host = 127.0.0.1
FixLayer.FixEngine.Session.FIXEDGE-SC2.IgnoreSeqNumTooLowAtLogon = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.IntradayLogoutTolerance = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.MaxMessagesAmountInBunch = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.Port = 444
FixLayer.FixEngine.Session.FIXEDGE-SC2.RecreateOnLogout = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.TerminateOnLogout = true
FixLayer.FixEngine.Session.FIXEDGE-SC2.RejectMessageWhileNoConnection = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.Role = Initiator
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderCompID = FIXEDGE
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.SocketPriority = EVEN
FixLayer.FixEngine.Session.FIXEDGE-SC2.SecurityGroups =
FixLayer.FixEngine.Session.FIXEDGE-SC2.StorageType = persistentmm
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetCompID = SC2
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.TcpBufferDisabled = false

BL_Config.xml

<Rule>
	<Source Name="FIXEDGE-SC1"/>
    <Action>
    	<Send Name="FIXEDGE-SC2" />
	</Action>
</Rule>

<Rule>
	<Source Name="FIXEDGE-SC2"/>
    <Action>
    	<Send Name="FIXEDGE-SC1" />
    </Action>
</Rule>

stunnel.conf

[ToStockExchange]
protocol = proxy
client = yes
accept  = 127.0.0.1:444
connect = x.x.x.x:443
 
[FromBroker]
protocol = proxy
accept  = y.y.y.y:443
connect = 127.0.0.1:8901

Server B (BROKER) Configuration

stunnel.conf

[FromBrokerToFIXEdge]
protocol = proxy
client = yes
accept  = 127.0.0.1:444
connect = y.y.y.y:443

[FromFIXEdgeToStockExchange]
protocol = proxy
accept  = x.x.x.x:443
connect = 127.0.0.1:9106

SimpleClient #1 conf

SenderCompID = SC1
TargetCompID = FIXEDGE
Remote host = 127.0.0.1
Remote port = 444

Set ListenPort in engine.properties to 9107 (ListenPort = 9107)

SimpleClient #2 conf

Set ListenPort in engine.properties to 9106 (ListenPort = 9106)

How to use

  1. Start SimpleClient #2
  2. Start FIXEdge - session between FIXEdge and SimpleClient #2 (SC2) should be established
  3. Start SimpleClient #1 (SC1) and establish session with FIXEdge using parameters from point 3
  4. Send application level messages from SimpleClient #1 - message will be routed to SimpleClient #2
  5. Send application level messages from SimpleClient #2 - message will be routed to SimpleClient #1

 

  • No labels