These parameters are used for managing heartbeats related to the connection with between FEJ and FIXICC H2.
Parameters used on FIXICC H2
Parameter Name | Description | Type | Default Value |
---|---|---|---|
fixicch2.heartbeat.job.interval.sec | The interval in seconds for the job that checks if it is needed to send a heartbeat to a server FEJ and if it is required to unsubscribe from some server and reconnect. | Integer | 5 |
fixicch2.sse.heartbeat.interval.sec | The heartbeat interval in seconds for Server-Sent Events (SSE). | Integer | 30 |
fixicch2.reconnectServerIfNoHeartbeats | If true, FIXICC - H2 should attempt to reconnect to a server FEJ if no SSE events are received during two consecutive heartbeat intervals defined by fixicch2.sse.heartbeat.interval.sec. | Boolean | true |
...
Parameter Name | Description | Type | Default Value |
---|---|---|---|
job.heartbeat.interval.sec | The interval in seconds for the job that checks if it is needed to send a heartbeat to FIXICC - H2 and if it is required to unsubscribe or reconnect. | Integer | 5 |
sse.heartbeat.interval.sec | The heartbeat interval in seconds for Server-Sent Events (SSE) from FIXICC - H2. | Integer | 30 |
reconnectIfNoHeartbeats | If true, FIXEdge Java FEJ should attempt to reconnect to FIXICC - H2 if no SSE events are received during two consecutive heartbeat intervals. | Boolean | true |
...