Simple configuration FIXEdge -> Stunnel -> SSL acceptor
Install stunnel
Download latest version installer from https://www.stunnel.org/downloads.html
Run installer and answer questions to generate certificate.
Configure stunnel
Initiator FIX session
- Run stunnel GUI Start from Start menuRun
- Edit stunnel.conf from stunnel system tray icon context menu
- Add option
protocol = proxy - Comment example SSL services
- Add SSL service
[fix_initiator_session1_tunnel]
client = yes
accept = 127.0.0.1:443
connect = 63.247.113.201:443
- Add option
- Run Reload stunnel.conf from stunnel system tray icon context menu
Configure fix session
Initiator FIX session
FixLayer.FixEngine.Session.SSLInitiator.Role = Initiator FixLayer.FixEngine.Session.SSLInitiator.Host = 127.0.0.1 FixLayer.FixEngine.Session.SSLInitiator.Port = 443
Complex configuration: Broker/Stock -> Broker's/Stock's Stunnel -> FIXEdge's Stunnel -> FIXEdge -> FIXEdge's Stunnel -> Broker's/Stock's Stunnel -> Broker/Stock
Server F (FIXEDGE): y.y.y.y where FIXEdge is installed
Server B (BROKER): x.x.x.x where SimpleClient #1 and SimpleClient #2 are installed. SimpleClient #1 will simulate Broker and SimpleClient #2 will simulate StockExchange.
F (FIXEDGE) CONFIGURATION:
1. FIXEdge.properties:
# -----------------[ SC1 AS ACCEPTOR SEND MESSAGE TO SC2 ] ------------------
FixLayer.FixEngine.Session.FIXEDGE-SC1.Version = FIX44
FixLayer.FixEngine.Session.FIXEDGE-SC1.EncryptMethod = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.ForceSeqNumReset = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.IgnoreSeqNumTooLowAtLogon = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.IntradayLogoutTolerance = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.MaxMessagesAmountInBunch = 0
FixLayer.FixEngine.Session.FIXEDGE-SC1.RecreateOnLogout = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.TerminateOnLogout = true
FixLayer.FixEngine.Session.FIXEDGE-SC1.RejectMessageWhileNoConnection = false
FixLayer.FixEngine.Session.FIXEDGE-SC1.Role = Acceptor
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderCompID = FIXEDGE
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.SenderSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.SocketPriority = EVEN
FixLayer.FixEngine.Session.FIXEDGE-SC1.SecurityGroups =
FixLayer.FixEngine.Session.FIXEDGE-SC1.StorageType = persistentmm
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetCompID = SC1
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.TargetSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC1.TcpBufferDisabled = false
# ----------------- [SC2 AS INITIATOR RECEIVED MESSAGES SENT FROM SC1] ----------
FixLayer.FixEngine.Session.FIXEDGE-SC2.Version = FIX44
FixLayer.FixEngine.Session.FIXEDGE-SC2.EncryptMethod = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.ForceReconnect = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.ForceSeqNumReset = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.HBI = 30
FixLayer.FixEngine.Session.FIXEDGE-SC2.Host = 127.0.0.1
FixLayer.FixEngine.Session.FIXEDGE-SC2.IgnoreSeqNumTooLowAtLogon = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.IntradayLogoutTolerance = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.MaxMessagesAmountInBunch = 0
FixLayer.FixEngine.Session.FIXEDGE-SC2.Port = 444
FixLayer.FixEngine.Session.FIXEDGE-SC2.RecreateOnLogout = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.TerminateOnLogout = true
FixLayer.FixEngine.Session.FIXEDGE-SC2.RejectMessageWhileNoConnection = false
FixLayer.FixEngine.Session.FIXEDGE-SC2.Role = Initiator
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderCompID = FIXEDGE
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.SenderSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.SocketPriority = EVEN
FixLayer.FixEngine.Session.FIXEDGE-SC2.SecurityGroups =
FixLayer.FixEngine.Session.FIXEDGE-SC2.StorageType = persistentmm
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetCompID = SC2
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetLocationID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.TargetSubID =
FixLayer.FixEngine.Session.FIXEDGE-SC2.TcpBufferDisabled = false
2. BL_Config.xml:
<Rule>
<Source Name="FIXEDGE-SC1"/>
<Action>
<Send Name="FIXEDGE-SC2" />
</Action>
</Rule>
<Rule>
<Source Name="FIXEDGE-SC2"/>
<Action>
<Send Name="FIXEDGE-SC1" />
</Action>
</Rule>
3. stunnel config:
[ToStockExchange]
protocol = proxy
client = yes
accept = 127.0.0.1:444
connect = x.x.x.x:443
[FromBroker]
protocol = proxy
accept = y.y.y.y:443
connect = 127.0.0.1:8901
B (BROKER) CONFIGURATION:
1. stunnel.conf:
[FromBrokerToFIXEdge]
protocol = proxy
client = yes
accept = 127.0.0.1:444
connect = y.y.y.y:443
[FromFIXEdgeToStockExchange]
protocol = proxy
accept = x.x.x.x:443
connect = 127.0.0.1:9106
2. SimpleClient #1 conf:
SenderCompID = SC1
TargetCompID = FIXEDGE
Remote host = 127.0.0.1
Remote port = 444
Set ListenPort in engine.properties to 9107 (ListenPort = 9107)
3. SimpleClient #2 conf:
Set ListenPort in engine.properties to 9106 (ListenPort = 9106)
Start SimpleClient #2
Start FIXEdge - session between FIXEdge and SimpleClient #2 (SC2) should be established
Start SimpleClient #1 (SC1) and establish session with FIXEdge using parameters from point 3
Send application level messages from SimpleClient #1 - message will be routed to SimpleClient #2
Send application level messages from SimpleClient #2 - message will be routed to SimpleClient #1